CE Heavy Industrial
Industrial Immunity and Emissions Testing Requirements per the Generic Standards
Applicable Standard |
Description |
Test or Measurement |
Required by EN61000-6-2: 2001 |
Required Criterion |
Electrostatic Discharge IEC 61000-4-2
|
Air Discharge ESD at up to +/- 8 kV and Contact Discharge at 4 kV at several points with 10 positive and 10 negative ‘hits’ per location. |
Air Direct
Air Indirect
Contact |
8KV
4KV
4KV |
B
B
B |
Radiated Immunity IEC 61000-4-3
|
Subject to electromagnetic field of 3V/m from 80 MHz to 1000 MHz. |
Modulated Frequency, Field |
1 kHz 80% AM 80-1000 MHz 10V/m except 87-108, 174-230 470-790MHz 3V/m |
A |
Electrical Fast Transient/Burst IEC 61000-4-4
|
EFT/Burst of 0.5 and 1.0 kV is coupled to the all I/O and control signals, respectively and 1.0 kV is injected on the Power Line. |
AC Line (Direct injection) DC Line (Direct Injection) Process Lines (Cap. Clamp) Signal Lines > 3m (Cap.Clamp) |
2 kV
2 kV
1 kV
1 kV |
B
B
B
B |
Surge Transient IEC 61000-4-5
|
5 Positive and 5 negative surges are applied to the power terminals at 0, 90 and 180 |
AC Lines Common Mode Diff. Mode |
2 kV 1 kV
|
B B
|
Conducted Immunity IEC 61000-4-6
|
Radio energy is coupled to Power and all I/O & control signals at 0.15 to 80 MHz. |
Power Line / Signal Lines Frequency Field Modulation |
0.15 – 80 MHz, 10 Vrms except 47-68 MHz 3 Vrms 80% AM, 1 kHz |
A
|
Power Frequency Magnetic Field IEC 61000-4-8 |
Magnetically susceptible apparatus is subject to a Magnetic Field of 30A (RMS) A/M, 50. |
Hz A/m |
50 or 60 30 CRT Interference allowed above 3 A/m |
A |
Voltage Dips and Interruptions IEC 61000-4-11
|
Voltage on the Power Lines Is reduced by 30 and 60 %. Voltage on the Power Lines Is interrupted for 5 seconds |
Dips
Interruptions |
30%, 10ms 60%, 100ms, 1000ms
95%, 5000ms |
B C
C |
Applicable Standard |
Test or Measurement |
Required by EN 61000-6-2: 2001 |
Notes: |
Conducted Emissions CISPR 11 |
Phase and Neutral Power lines |
0.15 – 30.0 MHz Class A Limits
|
Class B Limits are permissable, but have no bearing on Industrial Equipment |
Radiated Emissions CISPR 11 |
Horizontal and Vertical Polarization |
30-1000 MHz Class A Limits
|
Class B Limits are permissable, but have no bearing on Industrial Equipment |
Power line harmonics EN61000-3-2 |
The Power-Line Harmonics |
Maximum 1.08, 2.3, 0.43, 1.14, 0.3, 0.77, 0.23 A…. for 2nd to nth Harmonic
|
Required only for produuct rated at 16 A or less |
Power line Fluctuations EN61000-3-3
|
The Power-Line Harmonic Distortion |
Maximum Voltage Flicker of PST < 1, PLT < 0.65 |
Required only for produuct rated at 16 A or less |